From: Novel electrodiagnostic provocative techniques for the diagnosis of suspected tarsal tunnel syndrome
 | Normal MP amplitude by routine tests (No.:40) |  | Normal LP amplitude by routine tests (No.:33) | ||
Amplitude | No. | % | Amplitude | No. | % |
MP_EDCT | 28 | 70.0 | LP_EDCT | 28 | 84.8 |
MP_DST | 24 | 60.0 | LP_DST | 25 | 75.8 |
MP_SST | 25 | 62.5 | LP_SST | 21 | 63.6 |
 | Normal MP latency by routine tests (No.: 29) |  | Normal LP latency by routine tests (No.: 31) | ||
Latency | No. | % | Latency | No. | % |
MP_EDCT | 22 | 75.9 | LP_EDCT | 25 | 80.6 |
MP_DST | 15 | 51.7 | LP_DST | 22 | 71.0 |
MP_SST | 14 | 48.3 | LP_SST | 20 | 64.5 |